Small,
portable ultrasound systems which meet the increasing
expectations for concurrently diagnostic confidence
and highest productivity as well. User friendly
operation extends ultrasound diagnostics more
efficient and accurate, with maximum cost-performance.
These multipurpose systems are supported by a
wide-band probe family, for covering full range of
application requirements in Hospital Departments and
smaller Private Clinics. |
|
|
|
|
| |
TECHNICAL
SPECIFICATION:
|
|
|
|
|
| |
1. DISPLAY MODES
- B, B+B, 4B,B+Zoom, Zoom, M, B+M
- Option: PW (Pulse Wave Doppler)
- Option: Color Doppler: CF (Color Flow, PF (Power
Flow ),
B+CF/PF+PW |
|
|
|
|
| |
2. SCANNING MODES
- electronic linear / convex / micro-convex
|
|
|
|
|
| |
3. FEATURES
- color
Doppler module (option)

- SAS - Spectral Adaptive System
- THV - Tissue Harmonic Visualization
- ESR - Enhanced Speckles Reduction
- Dynamic aperture, apodization & mix-dynamic
focusing
- 5 zones of TGC control for each of the scan depth
- Gray scale 256
- Image memory 512 x 512 x 8
- Display: Hi-Res non-interlaced 10" LCD monitor
- Scanning frame rate up to 25 fps (automatically
optimized)
- M-mode sweep speed: selectable from about 2 to 9
sec/screen
- Zoom 6 steps
- Scanning depth range: from 2 cm to 25 cm
- Image orientation: L/R, Up/Dn, Pos./Neg.
- Cineloop memory (256-frames/screens)
- Digital filters - adaptive correlation, edge
enhancement, wall filter,
reject
- Gray scale postprocessing
- Image annotation: alphanumeric, comments, patient
information,
date, time, body marks
- Large, versatile trackball
- Independent report pages: B, M, PW, OB/GYN
- Probe interface: 1-2 electronical (+ 2 for special
probes)
- Easy upgrade and customize to specific diagnostic
requirements
|
|
|
|
|
| |
4. OPTIONAL EQUIPMENT
- videoprinter
B/W


- videoprinter
color


- biopsy
attachments 
- non-volatile
Image Memory (up to 1000 images)

- USB-Pen
Memory Module up to 2000 images capacity
(transfer images to PC using USB Pen Drive)

|
|
|
|
|
| |
5. MEASUREMENTS
B-mode:
- Distance (4 pairs of cursors)
- Area, circumference (ellipse, contour)
- Volume (ellipsoid, contour, 3-axis method)
- Urology calculations and others according to order
Prenatal calculation programs:
- BPD, CRL, FL, GS, AC, HC (factory & user table)
- fetal weight FW [AC/BPD]
- ratios calculation FL/BPD, HC/AC , FL/AC
- GA mean (automatic averaging of fetal age)
- automatic calculation of the date of birth EDD
- user and manufacturer table
M-mode:
- multi-measurement possibility
- time, velocity, amplitude (t, v, d)
- Heart rate (HR)
- LV measurement calculation: EDV, ESV, CO, SV, EF
- fast measurements of: AOD, LA , RVED, DE_Amp, IVS
Doppler PW:
- time, speed, acceleration (t, v, a)
- PHT, MVA, max. PG, mean PG, HR
- vessel index: A/B, RI, PI
|
|
|
|
|
| |
6. OUTPUTS
TV PAL for connection:
- auxiliary B/W monitor
- B/W videoprinter
- frame grabber PC cards |
|
|
|
|
| |
7. MULTI-FREQUENCY TRANSDUCER TYPES:
Electronic:
-
convex: CA-255 /R60
(2,5~5,0 MHz) 
- convex: CA-305/ R20
(2,5~6,0 MHz) 
- convex: CA-307/ R13
(3,0~7,0 MHz)
- convex: CA-409/ R13
(4,0~9,0 MHz)
- linear: LA-575 /L64
(5,0~7,5 MHz) 
- linear: LA-510 /L40
(5,0~10,0 MHz) 
- linear: LA-912 /L30
(9,0~12 MHz) 
- linear endorectal:
LR-575/L64 (5~7,5 MHz)

Mechanical:
- convex: S-255
/R15(2,5~5MHz) 
- convex: S-510
/R15 (5~10MHz) 
- micro-convex:
SM-457 /R10 (4,5~7MHz)

- micro-convex:
SR-457 /R10 (4,5~7 MHz)

|
|
|
|
|
| |
8. POWER SUPPLY
Power supply: AC 100/240 V, 50/60 Hz
Power consumption: 40 VA
Option: internal or car battery supply |
|
|
|
|
| |
9. DIMENSIONS AND WEIGHT
- 324 x 362 x 270mm; 8 kg*
- trolley: 465 x 512 x 775 ca. 8.2 kg
(*) depends on configuration |
|
|
|
|
|
ECHO-SON reserves the right to
change design and specification without notice. All
rights reserved. |
|
|
|
|
|
|
|
|
|
|