Small,
portable ultrasound systems which meet the increasing
expectations for concurrently diagnostic confidence
and highest productivity as well. User friendly
operation extends ultrasound diagnostics more
efficient and accurate, with maximum cost-performance.
These multipurpose systems are supported by a
wide-band probe family, for covering full range of
application requirements in Hospital Departments and
smaller Private Clinics. |
|
|
|
|
| |
TECHNICAL
SPECIFICATION:
|
|
|
|
|
| |
1. DISPLAY MODES
- B, B+B, 4B,B+Zoom, Zoom, M, B+M
|
|
|
|
|
| |
2. SCANNING MODES
- electronic linear / convex / micro-convex
- mechanical convex / sector, micro-convex |
|
|
|
|
| |
3. FEATURES
- portable general purpose diagnostic ultrasound
system
- probe interface: 1x electonic (option) i 2x
mechanical
- image memory: 512 x 512 x 8
- gray scale: 256 levels
- cineloop (256 frames)
- focusing: extended / elongated zone
- multi (4 foc. points)
- scan depth: 3-25 cm
- scanning rate: max. 25 frames / sec (automatic
optimum setting )
- 4 selectable sweep speed in M-mode
- 3 zones of TGC control for each of thescan depth
- image orientation: L/R, Up/Dn, Pos/Neg
- image processing:
- adaptive correlation: 4 steps
- postprocessing: 4 steps
- edge enhanced processing
- display information: Patient ID, date, time, name,
comments /
annotation
- Hi-Res. non interlaced 9" CRT monitor ( LCD:
10" -option )
- Zoom 6 steps
- large, versatile trackball
- all results of the measurements are stored on the
independent
report pages
- alphanumerical keyboard
|
|
|
|
|
| |
4. OPTIONAL EQUIPMENT
- trolley

- videoprinter
B/W


- videoprinter
color


- biopsy
attachments 
- non-volatile
Image Memory (up to 1000 images)

- USB-Pen
Memory Module up to 2000 images capacity
(transfer images to PC using USB Pen Drive)

|
|
|
|
|
| |
5. MEASUREMENTS
B-Mode:
- distance (4 pair of cursors)
- area, circumference (ellipse)
- volume (ellipsoid, 3 axis method)
Prenatal calculation programs:
- BPD, CRL, FL, GS, AC, HC(factory & user table)
- fetus weight FW (AC/BPD)
- ratio calculations: FL/BPD, HC/AC
- GA mean
- automatic calculation of birth date EDD
M-Mode:
- calculations of time, velocity, amplitude,heart rate
- cardiac measurements: EDV, ESV, CO,SV, EF
- fast measurements of AOD, LA, RVED,DE_Amp, IVS, PW
|
|
|
|
|
| |
6. OUTPUTS
TV PAL for connection:
- auxiliary B/W monitor
- B/W videoprinter
- frame grabber PC cards |
|
|
|
|
| |
7. MULTI-FREQUENCY TRANSDUCER TYPES:
Electronic:
-
convex: CA-255 /R60
(2,5~5,0 MHz) 
- convex: CA-305/ R20
(2,5~6,0 MHz) 
- convex: CA-307/ R13
(3,0~7,0 MHz)
- convex: CA-409/ R13
(4,0~9,0 MHz)
- linear: LA-575 /L64
(5,0~7,5 MHz) 
- linear: LA-510 /L40
(5,0~10,0 MHz) 
- linear: LA-912 /L30
(9,0~12 MHz) 
- linear endorectal:
LR-575/L64 (5~7,5 MHz)

Mechanical:
- convex: S-255
/R15(2,5~5MHz) 
- convex: S-510
/R15 (5~10MHz) 
- micro-convex:
SM-457 /R10 (4,5~7MHz)

- micro-convex:
SR-457 /R10 (4,5~7 MHz)

|
|
|
|
|
| |
8. POWER SUPPLY
- Power supply: AC
100/240 V, 50/60 Hz
- Power consumption: 40 VA |
|
|
|
|
| |
9. DIMENSIONS AND WEIGHT
- 335 x 590 x 110ca. 4.0 - 6.5 kg (*) (without
monitor)
- trolley: 465 x 512 x 775ca. 8.2 kg
(*) depends on configuration |
|
|
|
|
|
ECHO-SON reserves the right to
change design and specification without notice. All
rights reserved. |
|
|
|
|
|
|
|
|
|
|